메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Asif Naiyer (Department of Orthopaedic Surgery Faculty of Medicine JNMCH AMU Aligarh Uttar Pradesh India) Khan Mohammad Jesan (Department of Orthopaedic Surgery Faculty of Medicine JNMCH AMU Aligarh Uttar Pradesh India) Haris K. P. (Department of Orthopaedic Surgery Faculty of Medicine JNMCH AMU Aligarh Uttar Pradesh India) Waliullah Shah (Department of Orthopaedics KGMU Lucknow Uttar Pradesh India) Sharma Anubhav (Department of Orthopaedic Surgery Faculty of Medicine JNMCH AMU Aligarh Uttar Pradesh India) Firoz Danish (Department of Orthopaedic Surgery Faculty of Medicine JNMCH AMU Aligarh Uttar Pradesh India)
저널정보
대한슬관절학회 Knee Surgery and Related Research Knee Surgery and Related Research 제33권
발행연도
2021.12
수록면
42 - 42 (1page)
DOI
10.1186/s43019-021-00124-0

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Suspensory devices are extensively used in the management of anterior cruciate ligament (ACL) tear. They include fixed- and adjustable-loop devices. There are only a few studies comparing the efficacy of these two devices in the available literature. Therefore, the aim of this study is to compare clinical outcomes between the adjustable-loop device (group?I) and fixed-loop device (group?II).This was a prospective randomized study. Both groups were equivalent in demographic, preoperative, and intraoperative variables. Twenty-three patients underwent femoral side graft fixation with adjustable-loop and 20 with fixed-loop devices. Four patients were lost to follow-up. Assessment of clinical outcome was done with International Knee Documentation Committee (IKDC) score, Lysholm score, and knee stability tests (Lachman test and pivot shift test). Patient evaluation was performed preoperatively and finally postoperatively 2?years after surgery. Postoperative IKDC scores of group?I and II were 91.9?±?3.6 and 91.5?±?3.6, respectively, and Lysholm scores were 91.0?±?3.6 and 91.4?±?3.5, respectively, after 2?years; however, the difference in the outcomes was statistically insignificant ( p >?0.05). Twenty patients (87%) in group?I and 17 patients (85%) in group?II had a negative Lachman test ( p =?0.8). Twenty-two patients (95.7%) in group?I and 19 patients (95%) in group?II had a negative pivot shift test ( p =?0.9). ACL reconstruction with fixed- and adjustable-loop suspensory devices for graft fixation gives equivalent and satisfactory clinical results.1.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0